Perkin, M P; Picard, A*; Lecolinet, M*; Fen, K*; Sardi, M*; Miiler, A*; Agarwal, A*; Jescheck, M*; Wüthrich, C* (2008) Final report, CCM key comparison CCM.P-K2, pressure (10 kPa to 120 kPa) absolute mode. Metrologia, 45 (Tech, ). 07002.
Full text not available from this repository.Abstract
The results are presented of key comparison CCM.P-K2 that covered the pressure range 10 kPa to 120 kPa in absolute mode. Nine national measurement institutes participated in the comparison, which used a piston-cylinder assembly of 335 mm2 nominal effective area as a transfer standard.
Whilst not all laboratories were found to be equivalent at all pressures, the larger-than-expected instabilities in the transfer standard precluded the ability to discriminate between participant's standards at a level needed to fully support the Calibration Measurement Capabilities table in the BIPM key comparison database.
| Item Type: | Article | 
|---|---|
| Keywords: | pressure, key comparison | 
| Subjects: | Engineering Measurements Engineering Measurements > Mass, Force, Pressure | 
| Last Modified: | 02 Feb 2018 13:15 | 
| URI: | https://eprintspublications.npl.co.uk/id/eprint/4331 | 
|  | 