Knott, A J (1999) Uncertainty of force generation for forces above 1.2MN. NPL Report. CMAM 47
|
Text
cmam47.pdf Download (983kB) |
Abstract
This report details the 'build-up' calibration of the following NPL secondary force standard machines:
.5 MN hydraulic amplification machine;
.12 MN strain gauged hydraulic machine; and
30 MN strain gauged hydraulic machine.
The work described was performed in the period from October 1997 to September 1999, and formed deliverable 2.1.2 of Contract MPU 8/45: Mass Metrology 1996-99. This report covers the methods and equipment used to carry out the work, and analyses the results in terms of the
uncertainty of force generated by each machine.
| Item Type: | Report/Guide (NPL Report) |
|---|---|
| NPL Report No.: | CMAM 47 |
| Subjects: | Engineering Measurements Engineering Measurements > Mass, Force, Pressure |
| Last Modified: | 02 Feb 2018 13:18 |
| URI: | https://eprintspublications.npl.co.uk/id/eprint/1252 |
![]() |