Clarkson, P; Wright, P S (2005) A model based approach for the calibration of IEC standard flickermeters using complex waveforms. In: BEMC 2005 - British Electromagnetic Measurements Conference, 14-17 November 2005, NPL, UK.
|
Text
BEMC2005-10.pdf Download (248kB) |
Abstract
Current methods of calibrating IEC standard flickermeters rely on the known response of a standard flickermeter to basic waveforms. This paper describes an implementation of the IEC standard flickermeter, developed at NPL, in order to assess the response of the flickermeter to more complex waveforms, which are representative of signals that occur in practice.
| Item Type: | Conference or Workshop Item (UNSPECIFIED) |
|---|---|
| Subjects: | Electromagnetics Electromagnetics > Electrical Measurement |
| Last Modified: | 02 Feb 2018 13:16 |
| URI: | https://eprintspublications.npl.co.uk/id/eprint/3316 |
![]() |