Mulligan, D R; Gnaniah, S J P; Sims, G D (2003) Thermal analysis techniques for composites and adhesives (second edition). Measurement Good Practice Guide. 62
|
Text (Measurement Good Practice Guide No. 62)
mgpg62.pdf - Published Version Download (363kB) |
Abstract
This Measurement Good Practice Guide covers five thermal analysis techniques; DSC, TMDSC, DMA, DEA and DTUL. Each technique is described and measurement issues are discussed. Precision statements based on inter-laboratory testing are presented for DSC, TMDSC and DMA. Recommended procedures for each technique are included in the Guide.
Recommendations are made for the choice of technique for the measurement of degree-of-cure and measurement of service temperature for composites and adhesives. Although these measurements are related, they present different measurement challenges and the effectiveness of each technique for these measurements is discussed.
| Item Type: | Report/Guide (Measurement Good Practice Guide) |
|---|---|
| Notes: | NPL made every effort to ensure all information contained in this Good Practice Guide was correct at time of publication. NPL is not responsible for any errors, omissions or obsolescence, and does not accept any liability arising from the use of these Good Practice Guides. |
| Subjects: | Advanced Materials Advanced Materials > Composites Advanced Materials > Thermal Analysis of Materials |