Rushton, L M; Ellis, L M; Zipfel, J D; Bevington, P; Chalupczak, W (2024) Performance of a radio-frequency two-photon atomic magnetometer in different magnetic induction measurement geometries. Sensors, 24 (20). 6657
Preview |
Text
eid10170.pdf - Published Version Available under License Creative Commons Attribution. Download (667kB) | Preview |
Abstract
Measurements monitoring the inductive coupling between oscillating radio-frequency magnetic fields and objects of interest create versatile platforms for non-destructive testing. The benefits of ultra low frequency measurements, i.e., below 3~kHz, are sometimes outweighed by the fundamental and technical difficulties related to operating pick-up coils or other field sensors in this frequency range. Inductive measurements with the detection based on a two-photon interaction in rf atomic magnetometers address some of these issues, as the sensor gains an uplift in its operational frequency. The developments reported here integrate the fundamental and applied aspects of the two-photon process in magnetic induction measurements. In this paper, all spectral components of the two-photon process are identified, which result from the non-linear interactions between the rf fields and atoms. A method for the retrieval of the two-photon phase information, which is critical for inductive measurements, is also demonstrated. Furthermore, a self-compensation configuration is introduced, whereby high contrast measurements of defects can be obtained due to its insensitivity to the primary field, including using simplified instrumentation for this configuration by producing two rf fields with a single rf coil.
| Item Type: | Article |
|---|---|
| Subjects: | Time and Frequency > Optical Frequency Standards and Metrology |
| Divisions: | Time & Frequency |
| Identification number/DOI: | 10.3390/s24206657 |
| Last Modified: | 23 May 2025 13:53 |
| URI: | https://eprintspublications.npl.co.uk/id/eprint/10170 |
![]() |
Tools
Tools