The NPL standard flame: operating instructions.

Sutton, G J M (2016) The NPL standard flame: operating instructions. NPL Report. ENG 65

[img] Text
ENG65.pdf

Download (8MB)

Abstract

This report describes the operating instructions for the NPL portable standard flame system based on the Hencken flat flame burner using dry laboratory air and industrial grade (95% nominal purity) propane. It also includes a summary of the temperature field above the burner for equivalence ratios from phi = 0.8 to phi = 1.4, at an airflow rate of 23 SLPM.