EUROMET intercomparison of mercury triple point cells at NPL.

Head, D I (1994) EUROMET intercomparison of mercury triple point cells at NPL. NPL Report. QU 99

[img] Text
QU99.pdf

Download (1MB)

Abstract

Under a EUROMET agreement "Intercomparison of Mercury Point Cells" (A280) the INM mercury cell was measured at NPL and the melting plateaus compared with those of an NPL mercury cell. The results indicated an agreement in the value of the two cells to better than 0.1 mK. The estimated uncertainty of the comparison was 0.2 mK at 95% confidence.