Pearce, J V; Edler, F*; Elliott, C J; Failleau, G*; Morice, R*; Ogura, H* (2011) Investigation of Pd-C cells to improve thermocouple calibration. Metrologia, 48 (5). pp. 375-381.
Full text not available from this repository.Abstract
An intercomparison of the melting temperatures of four Pd-C eutectic fixed-point cells was performed by using four Pt/Pd thermocouples. The cells are designed for the calibration of thermocouples and were constructed in the participating laboratories of NPL, LNE, NMIJ, and PTB. The measurements were performed in four different high-temperature furnaces but by applying the same measurement procedure. In spite of slightly different cell designs and different material sources, the melting temperatures of three of the four Pd-C cells (NPL, LNE, and NMIJ) agreed very well within their expanded uncertainties of k = 2.
| Item Type: | Article |
|---|---|
| Keywords: | thermocouples, eutectic fixed points, high temperature fixed points, htfp, Pd-C, Pt/Pd |
| Subjects: | Engineering Measurements Engineering Measurements > Thermal |
| Identification number/DOI: | 10.1088/0026-1394/48/5/019 |
| Last Modified: | 02 Feb 2018 13:14 |
| URI: | https://eprintspublications.npl.co.uk/id/eprint/5277 |
![]() |