Bassler, N*; Hansen, J W*; Palmans, H; Holtzscheiter, M H*; Kovacevic, S* (2008) The antiproton depth dose curve measured with alanine detectors. Nucl. Instrum. Methods Phys. Res. B, Beam Interact. Mater. At., 266 (6). pp. 929-936.
Full text not available from this repository.Abstract
In this paper we report on the measurement of the antiproton depth dose curve, with alanine detectors. The results are compared with simulations using the particle energy spectrum calculated by FLUKA, and using the track structure model of Hansen et Olsen for conversion of calculated dose into response. A good agreement was observed between the measured and calculated relative effectiveness although a slight underestimation of the calculated values in the Bragg peak remains unexplained. The model prediction of response of alanine towards heavy charged particles encourages future use of the alanine detectors for dosimetry of mixed radiation fields.
| Item Type: | Article |
|---|---|
| Keywords: | Antiprotons, Depth dose curve, Alanine dosimetry, Relative effectiveness, Monte Carlo simulation |
| Subjects: | Ionising Radiation Ionising Radiation > Dosimetry |
| Last Modified: | 02 Feb 2018 13:15 |
| URI: | https://eprintspublications.npl.co.uk/id/eprint/4177 |
![]() |