Dose mapping of a Co60 industrial irradiation plant using an electronic data recording system, static measurements and mathematical modelling.

Sephton, J P; Sharpe, P H G; Chu, R D H*; O'Hara, K P J*; Abdel-Rehim, F*; Abdel Fattah, A* (2007) Dose mapping of a Co60 industrial irradiation plant using an electronic data recording system, static measurements and mathematical modelling. Radiat. Phys. Chem., 76 (11-12). pp. 1820-1825.

Full text not available from this repository.

Abstract

Dose rates at individual dwell points in a Co60 irradiation plant have been measured using electronic data recording and chemical dosimetry techniques. The measurements have been compared with calculations of the dose rate distribution using point kernal modelling. A description is given of a magnetic tape based data recording system that travels through the plant in an irradiation container. Values of dose rate and temperature are stored every 30 seconds with a total recording time of up to 8 hours. Dose rate distribution and integral dose data obtained from the electronic recorder were found to be in good overall agreement with chemical dosimetry and modelling.

Item Type: Article
Keywords: mathematical modelling, real time, dosimetry, alanine, ceric-cerous
Subjects: Ionising Radiation
Ionising Radiation > Dosimetry
Last Modified: 02 Feb 2018 13:15
URI: http://eprintspublications.npl.co.uk/id/eprint/3965

Actions (login required)

View Item View Item