Fry, A T (2002) Evaluation of the repeatability of residual stress measurements using x-ray diffraction. NPL Report. MATC(MN)19
Text
MATC_MN19.pdf Download (47kB) |
Abstract
This measurement note summarises extensive X-ray diffraction residual stress measurements conducted on three different materials. The purpose of the study was to investigate the repeatability of the XRD measurement method and the relative sensitivity of the measurement technique to changes in the test set-up, including the height offset of the specimen, the counting time and the number of Psi tilts used. Examples from the hot-peened spring steel sample are presented.
Item Type: | Report/Guide (NPL Report) |
---|---|
NPL Report No.: | MATC(MN)19 |
Keywords: | X-ray diffraction, accuracy, test set-up, repeatability, uncertainty, peak fitting |
Subjects: | Advanced Materials Advanced Materials > Mechanical Measurement |
Last Modified: | 02 Feb 2018 13:17 |
URI: | http://eprintspublications.npl.co.uk/id/eprint/2380 |