How to implement methods for uncertainty evaluation, with an application to the measurement of brain perfusion using a CFD-MRI simulation

Smith, Nadia (2018) How to implement methods for uncertainty evaluation, with an application to the measurement of brain perfusion using a CFD-MRI simulation. NPL Report. MS 23

[img]
Preview
Text (NPL Report MS 23)
MS23.pdf - Published Version

Download (531kB) | Preview

Abstract

This report aims to explain the implementation of methods for uncertainty evaluation, with an application to the measurement of brain perfusion using a Computational Fluid Dynamics (CFD)-Magnetic Resonance Imaging (MRI) simulation. This report is the main output of the activity between the National Physical Laboratory (NPL) and Gold Standard Phantoms (GSP) as part of the Innovate UK Analysis for Innovators (A4I) project to create a traceable calibration for an MRI perfusion measurement. The project is a collaboration between GSP, NPL and the National Engineering Laboratory (NEL). Further details can be found on GSP¿s web site.

Item Type: Report/Guide (NPL Report)
NPL Report No.: MS 23
Subjects: Mathematics and Scientific Computing > Measurement Uncertainties
Divisions: Data Science
Last Modified: 25 Jan 2019 14:41
URI: http://eprintspublications.npl.co.uk/id/eprint/8257