Cartmell, I (1994) Evaluation of waveguide-to-coaxial-line adaptors at frequencies up to 40 GHz. NPL Report. DES 134
![]() |
Text
des134.pdf Download (25MB) |
Abstract
Four techniques for determining the loss of waveguide-to-coaxial-line adaptors have been evaluated. One method, known as the Adaptor Removal Technique used with Automatic Network Analysers offers a means of measuring the full s-parameters of a single adaptor over a given frequency range,whereas the remaining three techniques all measure the insertion loss of adaptor pairs and rely on calculations to determine the loss of each adaptor. The results obtained using the four techniques are compared for measurements of adaptors in three waveguide sizes, WG14 to APC7, WG22 to Type 'K', and conclusions on the accuracy of each technique are given.
Item Type: | Report/Guide (NPL Report) |
---|---|
NPL Report No.: | DES 134 |
Subjects: | Electromagnetics Electromagnetics > RF and Microwave |
Last Modified: | 02 Feb 2018 13:19 |
URI: | http://eprintspublications.npl.co.uk/id/eprint/73 |
Actions (login required)
![]() |