< back to main site

Publications

Equivalent capacitance substitution method for monopole antenna calibration.

Sugiura, A*; Alexander, M J; Knight, D A; Fujii, K* (2012) Equivalent capacitance substitution method for monopole antenna calibration. In: 2012 IEEE International Symposium on Electromagnetic Compatability - EMC 2012, 6-10 August 2012, Pittsburgh, PA, USA.

Full text not available from this repository.

Abstract

The International Special Committee on Radio Interference (CISPR) has included in the draft standard CISPR 16-1-6, the equivalent capacitance substitution method (ECSM) for the calibration of monopole antennas below 30 MHz. To provide background information on the ECSM for CISPR 16-1-6 currently discussed, the present paper investigates the principle and uncertainty analysis of the ECSM in detail.

Item Type: Conference or Workshop Item (UNSPECIFIED)
Subjects: Electromagnetics
Electromagnetics > RF and Microwave
Identification number/DOI: 10.1109/ISEMC.2012.6351647
Last Modified: 02 Feb 2018 13:14
URI: http://eprintspublications.npl.co.uk/id/eprint/5661