Traceable measurement of source and receiver EVM using a real-time oscilloscope.

Humphreys, D A; Miall, J (2012) Traceable measurement of source and receiver EVM using a real-time oscilloscope. In: 2012 Conference on Precision Electromagnetic Measurements (CPEM 2012), 1-6 July 2012, Washington DC, USA.

Full text not available from this repository.

Abstract

A method to traceably calibrate Wideband Code Division Multiple Access (WCDMA) Error Vector Magnitude (EVM) contributions of a source or receiver is described using a Real-Time Digital Oscilloscope as the reference receiver. The results and uncertainties are presented for a receiver calibrated using four WCDMA sources from different manufacturers. The weighted mean EVM of the receiver at 900 MHz is 0.35 ±0.03 % at 95% confidence.

Item Type: Conference or Workshop Item (UNSPECIFIED)
Keywords: EVM, WCDMA, Mobile Telecommunications, Calibration, Traceability