Howes, J; Thompson, R (2005) A fully automated AF series substitution RF attenuation measurement system. In: BEMC 2005 - British Electromagnetic Measurements Conference, 14-17 November 2005, NPL, UK.
![]() |
Text
BEMC2005-2.pdf Download (228kB) |
Abstract
The series substitution technique is one of the most accurate methods for measuring RF and Microwave attenuation and is capable of making measurements exceeding 150 dB at RF frequencies with uncertainties of the order of ± 0.001 dB per 20 dB. This paper details such a system incorporating an automatic inductive voltage divider as its attenuation reference.
Item Type: | Conference or Workshop Item (UNSPECIFIED) |
---|---|
Keywords: | radio frequency, insertion loss |
Subjects: | Electromagnetics Electromagnetics > RF and Microwave |
Last Modified: | 02 Feb 2018 13:16 |