A comparison of complex scattering coefficient measurements in 50ohm coaxial line to 26.5GHz.

Ridler, N M; Medley, J C (1995) A comparison of complex scattering coefficient measurements in 50ohm coaxial line to 26.5GHz. NPL Report. DES 138

[img] Text
des138.pdf

Download (9MB)

Abstract

This report describes an exercise to compare complex scattering coefficient measurements of two-port items fitted with GPC-3.5 connectors in 50 ohm coaxial line. The measurements were made over the frequency range 1 GHz to 26.5 GHz. Results are presented in graphical form, together with a statistical summary of the measured values. Details of repeatability and drift assessments are also included. The eight participants are all members of ANAMET, which organised the administration and funding of the exercise.