Ives, D J (2001) Measurement of polarisation dependent responsivity of optical fibre power meters and optical spectrum analysers. In: OFMC'01 6th Optical Fibre Measurement Conference, 26-28 September 2001, Girton College, Cambridge, UK.
Full text not available from this repository.Abstract
Many of the sources used in optical fibre systems are highly polarised and this for highly accurate power measurements the polarisation dependent response (PDR) of the power meter becomes an important parameter. The use of Optical Spectrum Analysers (OSA) to test components and measure the relative powers in WDM systems requires the OSA to have a low PDR since the polarisation state may be a function of the wavelength. I report here the use of the fixed polarisation states measurement technique, similar to that used to measure PDL, to measure PDR of a number of integrating sphere type detectors and an OSA.