Sinclair, M W; Sharpe-Neale, P H W; Wait, D F*; Erard, L*; Buchholz, F I*; Somlo, P I*; Dexiong, X* (2001) International comparison CCEM.RF-K2.W (GT-RF-78-13) on noise power in IEC-R100 waveguide - final report. NPL Report. CETM 35
![]() |
Text
cetm35.pdf Download (4MB) |
Abstract
This report describes the measurements and results of international comparison CCEM.RF-K2.W (formly known as GT-RF-78-13) on noise power in IEC-R100 waveguide, which took place between September 1985 and April 1992. With the inception of the Mutual Recognition Arrangement (MRA) between National Measurement Institutes in 1999 it was decided that this comparison should be designated as an Intrim Key Comparison approved for provisional equivalence under MRA. For approval for provisional equivalence all measurement results must be published and this report is being published to fulfill this requirement.
Item Type: | Report/Guide (NPL Report) |
---|---|
NPL Report No.: | CETM 35 |
Subjects: | Electromagnetics Electromagnetics > RF and Microwave |
Last Modified: | 02 Feb 2018 13:17 |
URI: | http://eprintspublications.npl.co.uk/id/eprint/2095 |