Awan, S A; Kibble, B P; Robinson, I A (2000) Calibration of IVDs at frequencies up to 1MHz by permuting capacitors. IEE Proc. Sci. Meas. Technol., 147 (4). pp. 193-195.
Full text not available from this repository.Abstract
A device has been constructed which permutes eleven nominally equal 50pF capacitors in a bridge to calibrate the 10:1 and 1:10 ratios of inductive voltage dividers (IVDs) at frequencies up to 1 MHz. A compact design. which is important for high frequency measurements, was implemented using printed circuit boards and ceramic NPO dielectric capacitors. The capacitors are individually shielded to reduce errors from stray capacitances. Comparisons made with results from an existing NPL method of calibrating IVDs at frequencies up to 100 kHz and with results from a recently developed high-frequency four-pair bridge show that better than 10 parts-per-million uncertainty has been attained at 1 MHz.
Item Type: | Article |
---|---|
Subjects: | Electromagnetics |
Last Modified: | 02 Feb 2018 13:17 |
URI: | http://eprintspublications.npl.co.uk/id/eprint/2057 |
Actions (login required)
![]() |
View Item |