Ferriss, D H; Quested, P N (2000) Some comparisons of the Rosco and Beckwith-Newell analyses for the determination of viscosity of liquid metals using the oscillating cup viscometer. NMW 5.08 The choice of equations for the measurement of viscosity by the oscillating cylinder method. NPL Report. CMMT(A)306
Text
CMMT306.pdf Download (1MB) |
Abstract
It is shown that a small error exists in much of the literature quoting the Roscoe equation for the determination of viscosity using an oscillating cup viscometer. Typical data from experiments with liquid metals are analysed using the correct Roscoe equation and the Beckwith-Newell formula. Comparison of the result indicate that the formulæ are essentially equivalent. There is a brief discussion on the role of wetting of the crucible by the liquid under investigation and end effects.
Item Type: | Report/Guide (NPL Report) |
---|---|
NPL Report No.: | CMMT(A)306 |
Subjects: | Advanced Materials Advanced Materials > Thermal Analysis of Materials |
Last Modified: | 02 Feb 2018 13:17 |
URI: | http://eprintspublications.npl.co.uk/id/eprint/1876 |
Actions (login required)
View Item |