Low uncertainty centre of mass measurements using a weighbridge and calibration artefact

Berry, J J; Trenkel, C; Conceicao, P; Stock, M (2026) Low uncertainty centre of mass measurements using a weighbridge and calibration artefact. Measurement Science and Technology, 37 (16). 165005 ISSN 0957-0233

Full text not available from this repository.

Abstract

The precise location of the centre of mass of an object can be determined using a simple ‘weighbridge’. The weighbridge technique in conjunction with a well characterised calibration artefact has been applied to the centre of mass determination of a gravitational sensor proof mass. The measurements and the resulting uncertainty budget demonstrate that a standard uncertainty of less than 10 µm in the determination of the centre of mass position is possible.

Item Type: Article
Subjects: Engineering Measurements > Mass, Force, Pressure
Divisions: Materials and Mechanical Metrology
Identification number/DOI: 10.1088/1361-6501/ae5e37
Last Modified: 14 Sep 2026 14:47
URI: https://eprintspublications.npl.co.uk/id/eprint/10524