< back to main site

Publications

Reference characterisation of sound speed and attenuation of the IEC agar-based tissue-mimicking material up to a frequency of 60 MHz.

Rajagopal, S; Sadhoo, N; Zeqiri, B (2015) Reference characterisation of sound speed and attenuation of the IEC agar-based tissue-mimicking material up to a frequency of 60 MHz. Ultrasound Med. Biol., 41 (1). pp. 317-333.

Full text not available from this repository.

Abstract

To support the development of clinical applications of high-frequency ultrasound, appropriate tissue-mimicking materials (TMMs) are required whose acoustic properties have been measured using validated techniques. This paper describes the characterisation of the sound speed (phase velocity) and attenuation coefficient of the International Electrotechnical Commission (IEC) agar-based TMM over the frequency range 1 MHz to 60 MHz. Measurements implemented a broadband through-transmission substitution immersion technique over two overlapping frequency ranges, with co-axially aligned 50 MHz centre-frequency transducers employed for characterisation above 15 MHz. In keeping with usual practice employed within the technical literature, thin acoustic windows (membranes) made of 12 µm thick Mylar® protected the TMM from water damage. Various important sources of uncertainty which could compromise measurement accuracy have been identified and evaluated through a combination of experimental studies and modelling. These include TMM sample-thickness, measured both manually and acoustically, and the influence of interfacial losses that, even for thin protective membranes, are significant at the frequencies of interest. In agreement with previous reports, the attenuation coefficient of the IEC TMM exhibited a nonlinear frequency dependence, particularly above 20 MHz, yielding a value of 0.93 ± 0.04 dB cm-1 MHz-1 at 60 MHz, derived at 21 ºC ± 0.5 ºC. For the first time, phase velocity, measured with an estimated uncertainty of ± 3.1 m s-1, has been shown to be dispersive over this extended frequency range, increasing from 1541 m s-1 at 1 MHz to 1547 m s-1 at 60 MHz. This work will help standardise acoustic property measurements, and establishes a reference measurement capability for TMMs underpinning clinical applications at elevated frequencies.

Item Type: Article
Keywords: Ultrasound, tissue-mimicking material, speed of sound, attenuation coefficient, frequency dependence
Subjects: Acoustics
Acoustics > Ultrasound
Identification number/DOI: 10.1016/j.ultrasmedbio.2014.04.018
Last Modified: 02 Feb 2018 13:13
URI: http://eprintspublications.npl.co.uk/id/eprint/6541

Actions (login required)

View Item View Item